欢迎您光临江南游戏网址 网站!
联系江南游戏网址 / Contact us

江南游戏网址

客户咨询热线

0531-85767688

售后热线:15668327566

联系基地:山东省 德州市协同发展产业园D06幢

当前位置: 首页> 新闻中心> 公司新闻

桥架的连接件在安装时要注意什么?

文章来源://www.comprepyme.com/作者:电缆桥架厂家发布时间:2023-06-23浏览次数:12

返回: 公司新闻
桥架在安装的时候直线阶段之间还有弯通变形直通的连接件, 应采用桥架制造厂配套的连接件。连接件薄钢板厚度不应小于桥架薄钢板厚度。接口应平整,无扭曲、凸起和凹陷,连接用的半园头镀锌螺栓,半园头应在桥架内侧,螺栓长度适当,拧紧之后,露出长度以2~5牙为宜。水平安装的桥架,其直线段的连接头,应尽量设在两个支吊架之间的1/4左右处。
During the installation of the bridge, there are also curved, deformed, and straight connectors between the straight stages, which should be matched by the bridge manufacturer. The thickness of the connecting thin steel plate should not be less than the thickness of the bridge thin steel plate. The interface should be flat, without distortion, protrusion, or depression. The half round head galvanized bolts used for connection should be on the inner side of the bridge, and the bolt length should be appropriate. After tightening, the exposed length should be 2-5 teeth. For horizontally installed cable trays, the connection head of the straight section should be set at around 1/4 of the distance between the two supports and hangers as much as possible.
1.一般情况下不在施工现场制作桥架。由于特殊原因必需时,可利用现有的桥架改制非标准弯通和变径直通。改制和切断直线段桥架时,均不得用气、电焊切割,应用专用切割工具。改制的桥架必须平整,及时补漆,面漆颜色应与其它桥架相近。因为新建建筑物里,桥架安装一般都在混凝土结构工程完成数月甚至一年之后进行,混凝土收缩逐渐减小。伸缩量一般不会超过建筑物伸缩缝宽L。
1. Generally, cable trays are not manufactured on the construction site. If necessary due to special reasons, existing cable trays can be used to modify non-standard bends and variable diameter straights. When restructuring and cutting straight section cable trays, gas or electric welding cutting is not allowed, and special cutting tools should be used. The restructured cable tray must be flat, repainted in a timely manner, and the color of the topcoat should be similar to other cable trays. In new buildings, the bridge installation is usually carried out months or even a year after the completion of the concrete Structural engineering, and the concrete shrinkage gradually decreases. Generally, the expansion amount will not exceed the width L of building Expansion joint.
2.桥架跨越建筑物的伸缩缝处,按GB50168规定,应设置伸缩缝,保证桥架及敷设在桥架内的电缆在建筑物伸缩不危及其本身安全时能自由伸缩,不受损坏。
济南电缆桥架 济南电缆桥架
2. At the Expansion joint where the bridge crosses the building, Expansion joint shall be set according to GB50168 to ensure that the bridge and the cable laid in the bridge can expand freely without damage when the expansion of the building does not endanger its own safety.
3.若发现或从土建单位了解到建筑物伸缩缝较大有可能超过L时,以便于在桥架中留电缆(或电线)的伸缩余量,这个余量应大于伸缩缝宽L。应按实际做好伸缩处理。要跨越伸缩缝的桥架至少一侧有较长的直线段,宜超过30m,或伸缩缝两侧直线段桥架相加有30m,中间无水平或垂直弯通。
3. If it is found or learned from the civil engineering unit that the expansion joint of the building is large and may exceed L, so as to leave expansion allowance for cables (or wires) in the bridge, this allowance should be greater than the width of expansion joint L. Expansion and contraction treatment should be done according to the actual situation. At least one side of the bridge to cross the Expansion joint has a long straight section, which should exceed 30m, or the straight section bridges on both sides of the Expansion joint add up to 30m, and there is no horizontal or vertical bend in the middle.
工程案例 / Case Show
  • 济南火车站济南火车站
  • 曲阜孔子文化会展中心曲阜孔子文化会展中心
  • 山东工艺美院山东工艺美院
  • 公安厅服务展示公安厅服务展示
推荐资讯 / Recommended news
  • 槽式电缆桥架安装高度为什么有标准?槽式电缆桥架安装高度为什么有标准?

    电缆的散热效果:在电缆的运行过程中,会产生一定的热量。如果桥架安装高度过低,可能会导致电缆的散热效果不佳,从而使电缆过热,引发火灾等安全事故。因此,在安装桥架时,应确保其高度能够使电缆保持良好的散热状

    TIME:2024-01-22
Baidu
map