母线槽在安装维修装卸储存等方面的做法

文章来源://www.comprepyme.com/作者:电缆桥架厂家发布时间:2022-07-01浏览次数:10

返回: 行业动态
母线槽在使用过程中我们经常会遇到一些麻烦,下面我向大家介绍一下简单的使用注意事项,比如在安装维修装卸储存等方面的做法内容,希望使用人员注意安全使用。
We often encounter some troubles in the use of bus duct. Next, I will introduce some simple precautions for use, such as the practices in installation, maintenance, loading, unloading and storage. I hope users can pay attention to safe use.
母线槽安装:
Bus duct installation:
整个干线系统由多段母线槽单元(按照相应的出厂~编号)插接组装而成:每两段母线槽插接安装完毕后,两盖板端头之间的距离为200mm;
The whole trunk system is assembled by inserting multiple bus duct units (according to the corresponding factory ~ number): after inserting and installing each two bus ducts, the distance between the ends of the two cover plates is 200mm;
将两段母线槽两端相互插入后,穿入绝缘螺栓,垫入碗形垫片,用力矩扳手将螺栓拧紧,然后装上接头盖板,扭紧接头螺栓。紧固后的检验要求用0.01mm塞尺检查,应插不进去为宜;
After inserting the two ends of the two bus ducts into each other, insert the insulating bolts, pad the bowl shaped gaskets, tighten the bolts with a torque wrench, then install the joint cover plate and tighten the joint bolts. The inspection after fastening requires 0.01mm feeler gauge to be used for inspection, which should not be inserted;
通电前必须对母线槽系统进行相位和连接性试验。检查接地电阻和绝缘电阻,绝缘必须用1000V或500V兆欧表测其冷态绝缘电阻,每段不低于20M;
Phase and connectivity tests must be carried out on the bus duct system before energization. Check the grounding resistance and insulation resistance. The insulation must be measured with a 1000V or 500V megger in cold state, and each section is not less than 20m;
安装完毕后,应核对相位,确保无误,在TN-S系统中,PE线与N线严禁接错。母线槽受电时,不带有负载的所有母线馈电装置均应处于分断状态,受电后,必须测量每只分线箱,确保输入电压正常稳定,不缺相。
After installation, the phase shall be checked to ensure that there is no error. In TN-S system, PE line and N line shall not be connected incorrectly. When the bus duct is powered on, all bus feeder devices without load should be in the breaking state. After being powered on, each junction box must be measured to ensure that the input voltage is normal and stable without phase loss.
母线槽维修:
Bus duct maintenance:
1、必须切断母线槽电源,才能进行维护保养工作;
1. The power supply of bus duct must be cut off before maintenance;
2、使用三个月后须停电检查连接螺栓紧固情况,每年进行全面检查;
2. After three months of use, the power must be cut off to check the fastening of connecting bolts, and a comprehensive inspection should be carried out every year;
3、出现异常情况请立即断电检查,确定情况后再作处理;
3. In case of any abnormal condition, please cut off the power immediately for inspection, and deal with it after confirming the condition;
山东电缆桥架厂家
4、必须消除影响母线槽正常运行的不利因素,如滴水、导电粉尘、热源等;
4. The adverse factors affecting the normal operation of bus duct must be eliminated, such as dripping water, conductive dust, heat source, etc;
母线槽装卸:
Bus duct handling:
1、全过程防止潮湿、雨淋、化学物质的侵入;
1. Prevent moisture, rain and chemical intrusion in the whole process;
2、小心装卸、避免母线槽扭曲、碰撞、重压;
2. Handle with care to avoid distortion, collision and heavy pressure of bus duct;
3、装卸时,必须在中心起吊,不可在地面或槽体之间拖拉;
3. When loading and unloading, it must be lifted in the center, and it is not allowed to drag between the ground or the tank;
4、装卸工具建议使用叉车较为方便;
4. It is recommended to use forklift for loading and unloading tools;
、母线槽储存:
Storage of bus duct:
1、防止灰尘、液体侵入,并远离通道;
1. Prevent the invasion of dust and liquid, and keep away from the channel;
2、不要储存在室外,避免阳光曝晒;
2. Do not store it outdoors and avoid exposure to the sun;
3、母线槽堆放应在等高的木块隔开,多不超过5层;
3. Busbar trunking shall be stacked in equal height wood blocks, with no more than 5 layers;
4、 山东电缆桥架厂家建议您在安装母线槽前不要将包装物全部拆除。
4. Shandong cable tray manufacturer recommends that you do not remove all the packaging before installing the bus duct.
通过以上文章,大家可以清楚的了解到问题内容了,相信大家读完这篇文章,可以对该产品该事项有一个更加深入的了解,后续大家想了解更多相关知识内容,可以持续关注我们的官网 //www.comprepyme.com,有什么需要大家随时联系我们。
Through the above article, you can clearly understand the content of the problem. I believe that after reading this article, you can have a more in-depth understanding of the product and the matter. In the future, if you want to know more relevant knowledge, you can continue to pay attention to our official website //www.comprepyme.com , please feel free to contact us if you need anything.
工程案例 / Case Show
  • 济南火车站济南火车站
  • 曲阜孔子文化会展中心曲阜孔子文化会展中心
  • 山东工艺美院山东工艺美院
  • 公安厅服务展示公安厅服务展示
推荐资讯 / Recommended news
  • 槽式电缆桥架安装高度为什么有标准?槽式电缆桥架安装高度为什么有标准?

    电缆的散热效果:在电缆的运行过程中,会产生一定的热量。如果桥架安装高度过低,可能会导致电缆的散热效果不佳,从而使电缆过热,引发火灾等安全事故。因此,在安装桥架时,应确保其高度能够使电缆保持良好的散热状

    TIME:2024-01-22